Oxygen 4
Digital
Software version: Oxy4DGT V1.0.0.5 - 18 Jun 2004
Manual version: V1.2 - 29 Jul 2009
Vista de página 0
1 2 3 4 5 6 ... 71 72

Resumo do Conteúdo

Página 1 - Oxygen 4

Oxygen 4 Digital Software version: Oxy4DGT V1.0.0.5 - 18 Jun 2004 Manual version: V1.2 - 29 Jul 2009

Página 2 - PRODUCT SAFETY

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 10 5 Audio Signal Path CUE Aux Pre Aux Post Prog

Página 3

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 11 5.3 Outputs For the Prog, Sub, Aux, Cleanfeed 1,

Página 4 - Axel Technology

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 12 6 Analog/Digital levels with the Oxygen 4 Digital

Página 5

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 13 To summarize things shortly: 0 dB on your meter i

Página 6

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 14 7 Network Basics This chapter gives you a short ov

Página 7 - 1 Introduction

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 15 TCP/IP is a protocol that is well known in WAN stru

Página 8 - 2 Contents of the package

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 16 7.3.2 Subnets and Subnet Masks A subnet is a par

Página 9 - 4 System structure

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 17 7.3.5 DHCP DHCP stands for: “Dynamic Host Configu

Página 10 - 5 Audio Signal Path

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 18 8 Cobranet Basics This chapter gives you informati

Página 11 - 5.3 Outputs

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 19 9 Hardware Connections This chapter will describe

Página 12

PRODUCT SAFETY PRODUCT SAFETY This product is manufactured with the highest standards and is double-checked in our quality control department for

Página 13 - 0 dB on your meter is:

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 20 Figure 7: Microphone inputs at rear side The MIC

Página 14 - 7 Network Basics

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 21 9.1.2 LINE inputs The Oxygen 4 Digital can connec

Página 15

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 22 9.1.3 External inputs The Oxygen 4 Digital can sum

Página 16

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 23 Figure 11: Phones output at 19" rack 9.2 Dig

Página 17

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 24 9.3 Global Inputs/Outputs 9.3.1 GPIOs The in-/out

Página 18 - 8 Cobranet Basics

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 25 9.3.3 On-Air Output The GPO on the CRM connector

Página 19 - 9 Hardware Connections

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 26 9.3.6 Connection to Control Surfaces The control

Página 20

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 27 9.3.7 Cobranet (optional) CobraNet operates on a

Página 21

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 28 10 Using the Control Surface Figure 21: The 4-fad

Página 22

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 29 Figure 22: The 8-fader Control Surface of the Ox

Página 23 - 9.2 Digital Inputs/Outputs

Replace fuses always with the same type and rating after the equipment has been turned off and unplugged. If the fuse blows again you have an equipme

Página 24 - 9.3 Global Inputs/Outputs

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 30 10.1 Input routing The input signal can be proces

Página 25

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 31 10.4 Buss Routing When the signal has been proces

Página 26

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 32 10.5 Network settings through the Control Surface

Página 27

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 33 11 Webpage The control surface of the Oxygen 4 Dig

Página 28 - 10 Using the Control Surface

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 34 11.2 System information The System information s

Página 29

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 35 11.3 Network Settings The Network Settings scree

Página 30 - 10.3 Dynamic range control

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 36 Gateway Lets you change the gateway address. Thi

Página 31 - 10.4 Buss Routing

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 37 11.4 Cobranet Settings The Cobranet settings pag

Página 32

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 38 Read/Write Community The read/write community is a

Página 33 - 11 Webpage

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 39 11.5 Global Settings In the global setting scree

Página 34 - 11.2 System information

Dear Customer, Thank you for choosing the Oxygen 4 Digital Mixing console. The Oxygen 4 Digital is designed by specialists in the field of radio bro

Página 35 - 11.3 Network Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 40 CRM interlock If this option is enabled you can

Página 36

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 41 11.5.2 GPO 1 to 6 The GPO sends trigger-signals

Página 37 - 11.4 Cobranet Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 42 11.6 Input Settings The input settings menu is d

Página 38

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 43 11.6.1 Advanced input settings Figure 31.09: Ad

Página 39 - 11.5 Global Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 44 Local Function Audio On/Off enables you to disable

Página 40

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 45 11.7 Cobranet input Settings If Cobranet is not in

Página 41

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 46 11.8 Output Settings Figure 33.11: Output Setti

Página 42 - 11.6 Input Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 47 11.8.1 Advanced Output Settings Figure 34.12: O

Página 43

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 48 11.9 Cobranet Output Settings If Cobranet is not

Página 44

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 49 11.10 Security Settings The security setting of

Página 45 - 11.7 Cobranet input Settings

Oxygen4 Digital Mixer - Axel Technology- ,[email protected] Page 5 1 INTRODUCTION ...

Página 46 - 11.8 Output Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 50 11.10.1 Users and Levels Figure 37.15: User and

Página 47

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 51 Global Settings - EQ Range - Aux PRE/POST

Página 48

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 52 11.11 Chipcard Settings Figure 39.17: Chipcard

Página 49 - 11.10 Security Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 53 11.12 Control Surface Levels Figure 40.18: Contr

Página 50

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 54 11.13 Input Pool Levels Figure 41.19: Input Pool

Página 51

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 55 11.14 Network Levels With the network levels set

Página 52 - 11.11 Chipcard Settings

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 56 12 FTP The Oxygen 4 Digital also contains a FTP se

Página 53 - 11.12 Control Surface Levels

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 57 13 Oxygen 4 Digital EQ Tool The Oxygen 4 Digital h

Página 54 - 11.13 Input Pool Levels

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 58 14 ActiveX Application The ActiveX application is

Página 55 - 11.14 Network Levels

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 59 15 Specifications 15.1 General system parameters

Página 56 - 12.3 Flash

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 6 10.4.5 CRM ...

Página 57 - 13 Oxygen 4 Digital EQ Tool

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 60 15.7 Digital Outputs AES/EBU/AES3, S/P-DIF, Optica

Página 58 - 14 ActiveX Application

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 61 DECLARATION OF CONFORMITY Manufacturers Name:

Página 59 - 15 Specifications

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 62 Dear Oxygen 4 Digital owner, In this manual we

Página 60 - 15.10 Dimensions and Weight

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 63 16 List of Figures Figure 1: Audio Signal Flow...

Página 61 - DECLARATION OF CONFORMITY

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 64 17 List of Tables Table 1: Level Definitions ...

Página 62 - Dear Oxygen 4 Digital owner

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 65 18 Glossary dBFS...

Página 63 - 16 List of Figures

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 66 19 Appendix 19.1 Appendix A: Blockdiagram of the O

Página 64 - 17 List of Tables

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 67 19.2 Appendix B: Oxygen 4 Digital ActiveX Scripts

Página 65 - 18 Glossary

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 68 //1 = Unknown user //2 = Operator 1 //3 = Ope

Página 66 - Fixed Analog Outputs

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 69 Void SetGain(long ModuleNr, long Value) //Set Gai

Página 67

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 7 1 Introduction This manual will give you a detailed

Página 68

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 70 //Set Remote buss on or off // RemoteBussNr = 0 -&g

Página 69

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 71 //returns –140dB till 10dB Long GetCRMLevel() //r

Página 70

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 72 20 Disclaimer Due to a policy of continuous produc

Página 71

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 8 2 Contents of the package The following parts sh

Página 72 - 20 Disclaimer

Oxygen 4 Digital - from Axel Technology Phone +39 051736555, [email protected] Page 9 4 System structure The Oxygen 4 Digital system is

Comentários a estes Manuais

Sem comentários